An EasyEDA Copilot netlist export can fail after a schematic edit. In one case, restoring the pre-edit checkpoint restored the export. The cause was not confirmed, so this article describes the recovery and checks rather than a universal fix.
What happened
We edited net ports and wires on an EasyEDA Pro schematic through the Copilot API. The next full-schematic read returned Failed export netlist. A native component inspection did not show two expected net ports.
We restored the checkpoint made before the edit. The full-schematic read then succeeded, and its component records matched the pre-edit readback. This result does not identify the cause of the failure or prove that every graphical object was correct.
The MCP server reported version 1.3.3 and the extension reported version 1.3.2. The mismatch might matter, but we did not establish that it caused the failure.
Protect the project before an edit
- In EasyEDA Pro, save the current project and export a backup.
- In the Copilot workflow, identify the exact schematic page and save a checkpoint.
- Record the checkpoint ID and the page UUID.
- Export or record the baseline netlist and component-to-net assignments.
- Make one small change.
- Read the schematic again and compare the affected pins and nets with the baseline.
Use a separate project copy for experiments. A page checkpoint does not necessarily protect other pages, PCB documents, or project settings.
Recover after a failed export
- Stop further edits and record the error message.
- Check that the active document is the page you edited.
- Check that the operation has finished before you restore a checkpoint.
- Check that the pre-edit checkpoint belongs to that page and will not discard later work.
- Restore that specific checkpoint.
- Read the full schematic and compare the affected component pins and nets with the baseline.
- Review the schematic and run the available design checks before you update the PCB.
If you cannot identify a safe checkpoint, preserve the current project and inspect a backup. Do not restore an unrelated page or overwrite another person’s work.
Check the wire and net ports
In EasyEDA Pro, a wire has a name property. Its global net name can be the name used on the PCB. The EasyEDA Pro guide says that a wire connected to a net identifier follows that identifier. It also describes net-assignment prompts when wires split or merge.
- Open the affected schematic page.
- Select each changed wire and inspect its name and global net name in Properties.
- Inspect the net port and the wire endpoint at each affected pin.
- Highlight each affected net and compare its pin membership with the baseline.
- Repeat the full-schematic read before you import changes into the PCB.
These checks help locate a difference. They do not prove why an export failed. A correct-looking drawing alone does not prove electrical connectivity.
Isolate the failure in a project copy
A checkpoint restored export in our case. We have not identified a forward fix for the failed port edit.
- Export a project backup and create a separate project copy.
- In EasyEDA Pro, select Export > Netlist.
- Export the affected page and the whole project separately. Record each result.
- Compare each native export with a Copilot read of the same scope.
- On the copy, save a checkpoint and record the baseline pin-to-net assignments.
- Change one wire or port. Read the object and the netlist again.
- Compare connected pins, pins that must remain separate, and intentionally open pins.
- Stop at the first failure. Preserve the copy, error and version details for support.
Do not use a successful export or a clean design check as the only proof of connectivity. Do not repeat the production edit until the copy passes the checks.
Check the Copilot versions
Our MCP server reported 1.3.3, while the extension reported 1.3.2. Check both versions when you investigate. We did not prove that this mismatch caused the failure.
The Copilot 1.3.3 release notes describe a separate cleanup defect. Earlier extraction could remove pre-existing unconnected net ports. The release says 1.3.3 preserves them. We did not establish that this defect caused our failed export. Test a version change on a copy before you rely on it.
What remains unknown
We did not isolate whether the failure came from the port move, wire deletion, API behavior, version mismatch, or another condition. We did not verify a safe automated method to reposition those ports. Do not repeat the failed edit on a production design as a repair.